Experimental performance evaluation and model-based optimal design of a mechanical vapour recompression system for radioactive wastewater treatment

Publication Name

Energy Conversion and Management

Abstract

High-security and cost-effective disposal of radioactive wastewater plays a significant role in the wide deployment of nuclear energy. This paper presents an experimental study to investigate the feasibility of using mechanical vapour recompression systems for radioactive wastewater treatment, and a model-based design optimisation to maximise its economic benefits. A lab-scale mechanical vapour recompression system was established to experimentally assess its performance in terms of decontamination effect, energy efficiency, and exergy destruction. Based on the understanding of system performance, a numerical model for the proposed mechanical vapour recompression system was developed and validated, which was then utilised as a platform for optimal system design. A bi-objective design optimisation was formulated with the targets to minimise the payback period of the additional cost referencing to a traditional three-effect-evaporation system while maximising the system primary energy efficiency. Two intermediate variables, including the evaporation temperature and the heat transfer temperature difference, were selected as the optimisation variables. The experimental results verified the feasibility of using mechanical vapour recompression technology for radioactive wastewater treatment, demonstrating an excellent decontamination capability. It was found that an optimal evaporation temperature of 90 °C existed for maximising the decontamination factors for ions of strontium, cobalt, and cesium to 5.90 × 103, 1.45 × 104, and 1.74 × 104, respectively, while a higher system efficiency (coefficient of performance ranging from 7.33 to 8.21) has resulted when increasing the evaporation temperature (from 70 to 100 °C, correspondingly). The design optimisation resulted in an optimal Pareto front presenting the trade-off between the two optimisation objectives. By adopting the design corresponding to the optimal solutions identified, the mechanical vapour recompression system was found to feature a relative payback period of 0.69–2.32 years and a primary energy efficiency of 3.94–13.46, which outperformed a comparison case without optimisation (with that of 2.79 years and 3.03, respectively). The outcomes of study will provide guidance for the optimal application of mechanical vapour recompression evaporation system in nuclear wastewater treatment.

Open Access Status

This publication is not available as open access

Volume

252

Article Number

115087

Funding Number

E0ARJ30101

Funding Sponsor

Beijing Science and Technology Planning Project

Share

COinS
 

Link to publisher version (DOI)

http://dx.doi.org/10.1016/j.enconman.2021.115087