Abstract
The response of a solid state microdosimeter based on semiconductor on insulator (SOI) technology to a 238PuBe neutron source was investigated. Simulations of the device response using the GEANT4 Monte Carlo Toolkit are also presented. The microdosimetric spectra was measured for lineal energies above 1 keV/m. The possible application of the SOI microdosimeter for radiation protection applications in the form of a personnel microdosimeter is suggested.
Publication Details
This paper originally appeared as: Reinhard, MI, Cornelius, I, Prokopovich, DA et al, Response of a SOI Microdosimeter to a /sup 238/PuBe Neutron Source, IEEE Nuclear Science Symposium Conference Record, 23-29 October 2005, vol 1, 68-72. Copyright IEEE 2005.