Additional Publication Information
Hygrothermal Performance of Vapour-Permeable Wall Membranes in Cooler Australian Climates: Comparative Modelling and Sensitivity Analysis can be found here: https://ro.uow.edu.au/eispapers1/4584/
Abstract
This document has been prepared as an addendum to the report ‘Hygrothermal Performance of Vapour-Permeable Wall Membranes in Cooler Australian Climates: Comparative Modelling and Sensitivity Analysis’ [1] prepared by the Sustainable Buildings Research Centre (SBRC) at the University of Wollongong under the auspices of the Australian Research Council Hub for Australian Steel Innovation. It includes results from an additional set of hygrothermal simulations, as well as further explanation of certain assumptions in the original report.
Grant Number
ARC/IH200100005
Publication Details
Green, A & Cooper, P 2022, Hygrothermal Performance of Vapour-Permeable Wall Membranes in Cooler Australian Climates: Comparative Modelling and Sensitivity Analysis – Addendum, January 2022, Sustainable Buildings Research Centre, University of Wollongong