posted on 2024-11-18, 10:04authored byAlison Chapman
Intensity modulated radiation therapy (IMRT) is a relatively new treatment planning and delivery technique. The complex multiple-segment nature of an IMRT plan makes it difficult to verify using traditional look-up tables and hand calculations. The purpose of this project was to develop an effective and time-efficient plan checking procedure using a combination of ionisation chambers and film. The dosimeters available were 0.03 cc volume and 0.6 cc volume thimble ionisation chambers, Kodak X-Omat V (XV) film and Kodak Extende Dose Range (EDR2) film. First the dosimeters were tested for accuracy in terms of their dose response in the clinical range required (up to about 200 cGy). All were found to be suitable for further investigation for use in IMRT plan checking. One non-IMRT and six IMRT plans were validated. The plans were transferred from the patient geometry to a 30 cm x 30 cm x 30 cm cubic phantom made up of slabs of solid water. The ionisation chambers and films were calibrated and used to measure the dose delivered to the phantom at the isocentre for each beam and for an entire IMRT treatment. The film was also used to provide axial and planar dose distribution maps for comparison with the predicted distributions. Time restraints meant that not every type of dosimeter was used for every beam and treatment plan. It was found that the isocentric 0.6 cc volume ionisation chamber provided a suitably accurate dose check, with an average difference between predicted and measured full treatment doses of 2.0 cGy with a standard deviation of 2.7 cGy and 1.5% with a standard deviation of 2.1%. The film was less successful, with the EDR2 film (digitised and analysed using ImageJ software) giving an average difference between predicted and asured full treatment doses of 5.4 cGy with a standard deviation of 4.0 cGy and 4.0% with a standard deviation of 3.1%. The film was very useful for obtaining qualitative dose distribution maps, which could be used as surrogates to verify that the radiotherapy treatment planning system’s co-ordinate information was being transferred correctly. Following the results of the test cases a procedure was established for all future IMRT plans. The procedure can easily be varied to include further measurements if necessary, and consists of measuring the dose at isocentre from each beam and the whole treatment using the 0.6 cc ionisation chamber. EDR2 film is to be used to visually verify the axial dose distribution, and XV film to verify planar dose distributions for each beam.
History
Citation
Chapman, Alison, Dosimetric verification of intensity modulated radiation therapy, MSc thesis, Department of Engineering Physics, University of Wollongong, 2005. http://ro.uow.edu.au/theses/551
Year
2005
Thesis type
Masters thesis
Faculty/School
Department of Engineering Physics
Language
English
Disclaimer
Unless otherwise indicated, the views expressed in this thesis are those of the author and do not necessarily represent the views of the University of Wollongong.