A scintillation dual-detector system featuring active Compton suppression

thesis
posted on 2024-11-18, 10:01 authored by Dean Inwood
This thesis focuses on the performance characterisation of two prototype scintillation dual-detector radiation monitors that feature active gamma-ray collimation and the suppression of events caused by Compton scattering. This system is currently under development at the Centre for Medical Radiation Physics (CMRP) for radio-guided surgery and lymphoscintigraphy procedures involving low and high-energy gamma ray emitting isotopes. The two CMRP custom-designed configurations of dual-scintillator CsI(Tl) crystals were optically coupled to custom designed Si photodetectors. One configuration, nicknamed “CD1,” consists of an N--type Si base with P+-type circular inner and square outer regions, producing a p-n junction, while the other, “CD2,” consists of an N--type base with smaller P+-type circular inner and outer regions. Both CD1- and CD2-type configurations were investigated for their current-voltage characteristics, noise, crosstalk levels and system energy resolution for various radioisotopes. Both types of device were then integrated into a Compton-event suppression system. The devices were found to require a reverse bias voltage of not more than -60V for the CD1 type device and –30V for the CD2 type. Noise prevents the resolving of low energy peaks below around 150 keV for the CD1 type and below 100 keV for the CD2 type and crosstalk levels were found to be <2% on both types of device. Energy resolution of the CD1-type inner detector was found to be approximately 13% for Cs-137’s 662 keV peak and 8% for the CD2-type inner detector, while the resolution on the outer detector was found to be 21% for Cs-137’s 662 keV peak for the CD1 type and 19% for the CD2 type. Both devices were successfully integrated into a Compton event suppression system and achieved significant levels of suppression of Compton events that would otherwise contribute to the Compton continuum. These results indicate that the dual-detector system will be satisfactory for radio-guided surgery and lymphoscintigraphy using both low and highenergy radioisotopes.

History

Citation

Inwood, Dean, A scintillation dual-detector system featuring active Compton suppression, MSc-Res, Department of Engineering Physics, University of Wollongong, 2007. http://ro.uow.edu.au/theses/828

Year

2007

Thesis type

  • Masters thesis

Faculty/School

Department of Engineering Physics

Language

English

Disclaimer

Unless otherwise indicated, the views expressed in this thesis are those of the author and do not necessarily represent the views of the University of Wollongong.

Usage metrics

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC