University of Wollongong
Browse

Validation of the CrIS fast physical NH3 retrieval with ground-based FTIR

Download (3.59 MB)
journal contribution
posted on 2024-11-14, 23:45 authored by Enrico Dammers, Mark Shephard, Mathias Palm, Karen Cady-Pereira, Shannon Capps, Erik Lutsch, Kimberly Strong, James W Hannigan, Ivan Ortega, Geoffrey Toon, Wolfgang Stremme, Michel Grutter, Nicholas JonesNicholas Jones, D Smale, Jacob Siemons, Kevin Hrpcek, Denis Tremblay, Martijn Schaap, Justus Notholt, Jan Willem Erisman
Presented here is the validation of the CrIS (Cross-track Infrared Sounder) fast physical NH3 retrieval (CFPR) column and profile measurements using ground-based Fourier transform infrared (FTIR) observations. We use the total columns and profiles from seven FTIR sites in the Network for the Detection of Atmospheric Composition Change (NDACC) to validate the satellite data products. The overall FTIR and CrIS total columns have a positive correlation of r  =  0.77 (N  =  218) with very little bias (a slope of 1.02). Binning the comparisons by total column amounts, for concentrations larger than 1.0  x  1016 molecules cm−2, i.e. ranging from moderate to polluted conditions, the relative difference is on average ∼ 0-5 % with a standard deviation of 25-50 %, which is comparable to the estimated retrieval uncertainties in both CrIS and the FTIR. For the smallest total column range (< 1.0  x 1016 molecules cm−2) where there are a large number of observations at or near the CrIS noise level (detection limit) the absolute differences between CrIS and the FTIR total columns show a slight positive column bias. The CrIS and FTIR profile comparison differences are mostly within the range of the single-level retrieved profile values from estimated retrieval uncertainties, showing average differences in the range of  ∼ 20 to 40 %. The CrIS retrievals typically show good vertical sensitivity down into the boundary layer which typically peaks at  ∼ 850 hPa (∼ 1.5 km). At this level the median absolute difference is 0.87 (std  =  ±0.08) ppb, corresponding to a median relative difference of 39 % (std  =  ±2 %). Most of the absolute and relative profile comparison differences are in the range of the estimated retrieval uncertainties. At the surface, where CrIS typically has lower sensitivity, it tends to overestimate in low-concentration conditions and underestimate in higher atmospheric concentration conditions.

History

Citation

Dammers, E., Shephard, M., Palm, M., Cady-Pereira, K., Capps, S., Lutsch, E., Strong, K., Hannigan, J. W., Ortega, I., Toon, G. C., Stremme, W., Grutter, M., Jones, N., Smale, D., Siemons, J., Hrpcek, K., Tremblay, D., Schaap, M., Notholt, J. & Erisman, J. Willem. (2017). Validation of the CrIS fast physical NH3 retrieval with ground-based FTIR. Atmospheric Measurement Techniques, 10 (7), 2645-2667.

Journal title

Atmospheric Measurement Techniques

Volume

10

Issue

7

Pagination

2645-2667

Language

English

RIS ID

115675

Usage metrics

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC