University of Wollongong
Browse

File(s) not publicly available

The use of ultrasound imaging to measure midfoot plantar fat pad thickness in children

journal contribution
posted on 2024-11-14, 21:09 authored by Diane L Riddiford-Harland, Julie SteeleJulie Steele, Louise A Baur
STUDY DESIGN: Descriptive and reliability study. OBJECTIVES: To design a reliable imaging method to quantify the thickness of the medial midfoot plantar fat pad in the feet of young children and to determine any between-foot (right versus left) differences in thickness. BACKGROUND: Before we can establish whether persistent fat padding in the medial midfoot or a structural collapse of the longitudinal arch is the mechanism of flatter footprints displayed by obese children, a reliable method to quantify midfoot plantar fat pad thickness in children is required. METHODS AND MEASURES: A portable ultrasound imaging system was used to quantify medial midfoot plantar fat pad thickness for the right and left foot of 14 healthy children (mean ± SD: 3.8 ± 0.8 years) using 3 different measurement techniques. Intraclass correlation coefficients (ICC) and standard error of the measurement (SEM) were calculated to assess intrarater reliability of these measurement techniques. RESULTS: Medial midfoot plantar fat pad thickness (method 1, right foot) ranged from 3.1 to 4.9 mm. Similar values were observed for methods 2 and 3. The ICC values (0.82-0.94) and SEM values (0.12-0.23 mm) suggested that all 3 methods provided good reliability. Based on an ANOVA model, there was no significant interaction and no significant main effect for side, method, or day between the measurement techniques. CONCLUSIONS: We found ultrasonography to be a reliable field tool to quantify medial midfoot plantar fat pad thickness in children. Although there was no difference in reliability across the 3 measurement techniques, the technique in which the transducer was placed directly beneath the dorsal-navicular landmark was the most time-efficient procedure to measure the thickness of the midfoot plantar fat pad in young children.

History

Citation

Riddiford-Harland, D. L., Steele, J. R. & Baur, L. A. 2007, 'The use of ultrasound imaging to measure midfoot plantar fat pad thickness in children', Journal of Orthopaedic and Sports Physical Therapy, vol. 37, no. 10, pp. 644-647.

Journal title

Journal of Orthopaedic and Sports Physical Therapy

Volume

37

Issue

10

Pagination

644-647

Language

English

RIS ID

38721

Usage metrics

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC