posted on 2024-11-15, 08:40authored byNajdat AzizNajdat Aziz, Dean Majoor, Ali Mirzaghorbanali
An experimental study was carried out on grout samples prepared from both Stratabinder and BU100 cementitious products. Samples were prepared with various water to grout ratios and tested for uniaxial compressive and shear strength. Triaxial tests were performed on cylindrical samples to determine values for internal friction angle, cohesion and tensile strength. It was found that the water to cement ratio affects the uniaxial compressive and shear strength of grout. The triaxial test indicated that both internal friction angle and cohesion of Stratabinder do not differ significantly from BU100.
History
Citation
Aziz, N., Majoor, D. & Mirzaghorbanali, A. (2017). Strength properties of grout for strata reinforcement. Procedia Engineering, 191 1178-1184. Ostrava, Czech Republic ISRM European Rock Mechanics Symposium EUROCK 2017