University of Wollongong
Browse

File(s) not publicly available

Reference Phantom Method for Ultrasonic Imaging of Thin Dynamic Constructs

journal contribution
posted on 2024-11-17, 13:00 authored by Andres Ruland, James M Hill, Gordon G Wallace
Quantitative ultrasound has a great potential for the non-destructive evaluation of tissue engineered constructs, where the local attenuation and the integrated backscatter coefficient (IBC) can be used for monitoring the development of biological processes. The local determination of both parameters can be achieved using the reference phantom method (RPM). However, its accuracy can be affected when evaluating constructs of evolving sound speed, attenuation and thickness, for example, when evaluating biodegradable hydrogels developing neocartilage. To assess the feasibility of using the RPM under such dynamic conditions while employing a 50-MHz transducer, we conducted a series of experiments on 3-mm-thick acellular hydrogels laden with microspheres. The ultrasonic evaluation procedure used was validated by detecting and compensating for large attenuation variations occurring in the construct, up to 20-fold with respect to the reference phantom, with estimations errors below 1%. We found that sound speed mismatch does not affect the local attenuation estimation, but causes a strong diffraction effect by reducing the backscatter intensity. Such intensity reduction was compensated by determining the IBC percentage change (IBCΔ) as function of sound speed mismatch with respect to the reference phantom (ΔSS), with the equation IBCΔ = (0.63 ± 0.07) ΔSS + (8.54 ± 0.76) 10–3 ΔSS2. The investigated ΔSS interval was up to 120 m/s and using two different concentrations of microspheres, with estimation errors below 7% relative to the construct's actual IBC. Finally, we found that the spectral difference method is sufficient to measure within a few millimetres in depth mismatch, and when combining with sound speed mismatch, we found negligible additional effects. These results pave the way for the use of a generic reference phantom for the evaluation of thin dynamic constructs, thus simplifying the need for using different phantoms depending on the construct's properties.

Funding

Australian National Fabrication Facility (CE 140100012)

History

Journal title

Ultrasound in Medicine and Biology

Volume

47

Issue

8

Pagination

2388-2403

Language

English

Usage metrics

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC