University of Wollongong
Browse

Neutron dosimeter development based on Medipix2

Download (796.64 kB)
journal contribution
posted on 2024-11-15, 04:36 authored by Mohd Amir Othman, Marco PetaseccaMarco Petasecca, Susanna GuatelliSusanna Guatelli, J Uher, Damion Marinaro, Dale ProkopovichDale Prokopovich, Mark Reinhard, Michael LerchMichael Lerch, J Jakubek, S Pospisil, Anatoly RozenfeldAnatoly Rozenfeld
A novel neutron dosimetry system for avionics and space applications is described. The new dosimetric system is based on Medipix2, a high density silicon based pixilated detector with integrated readout and digital interface circuitry. Real time dose equivalent response to fast neutron fields with flattened energy response is achieved through the coupling of a structured variable thickness polyethylene (PE) over layer with the high density pixilated detector. Experimental results obtained to 14 MeV D-T and Am-Be neutron fields are described along with a comparison to results obtained with GEANT4 simulations.

History

Citation

Othman, M, Petasecca, M, Guatelli, S, Uher, J, Marinaro, D, Prokopovich, D, Reinhard, MI, Lerch, M LF, Jakubek, J, Pospisil, S & Rosenfeld, AB, 2010, Neutron dosimeter development based on Medipix2, IEEE Transactions on Nuclear Science, vol. 57, no. 6, 3456-3462.

Journal title

IEEE Transactions on Nuclear Science

Volume

57

Issue

6 PART 1

Pagination

3456-3462

Language

English

RIS ID

34903

Usage metrics

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC