University of Wollongong
Browse

Modeling a Thick Hydrogenated Amorphous Silicon Substrate for Ionizing Radiation Detectors

Download (2.62 MB)
journal contribution
posted on 2024-11-15, 22:44 authored by Jeremy DavisJeremy Davis, Maurizio Boscardin, Michele Crivellari, Livio Fano, Matthew Large, Mauro Menichelli, Arianna Morozzi, Francesco Moscatelli, Maria Movileanu-Ionica, Daniele Passeri, Marco PetaseccaMarco Petasecca, Mauro Piccini, Alessandro Rossi, Andrea Scorzoni, Bailey Thompson, Giovanni Verzellesi, Nicolas Wyrsch
© Copyright © 2020 Davis, Boscardin, Crivellari, Fanò, Large, Menichelli, Morozzi, Moscatelli, Movileanu-Ionica, Passeri, Petasecca, Piccini, Rossi, Scorzoni, Thompson, Verzellesi and Wyrsch. There is currently a renewed interest in hydrogenated amorphous silicon (a-Si:H) for use in particle detection applications. Whilst this material has been comprehensively investigated from a numerical perspective within the context of photovoltaic and imaging applications, the majority of work related to its application in particle detection has been limited to experimental studies. In this study, a material model to mimic the electrical and charge collection behavior of a-Si:H is developed using the SYNOPSYS©Technology Computer Aided Design (TCAD) simulation tool Sentaurus. The key focus of the model is concerned with the quasi-continuous defect distribution of acceptor and donor defects near the valence and conduction bands (tails states) and a Gaussian distribution of acceptor and donor defects within the mid-gap with the main parameters being the defect energy level, capture cross-section, and trap density. Currently, Sentaurus TCAD offers Poole-Frenkel mobility and trap models, however, these were deemed to be incompatible with thick a-Si:H substrates. With the addition of a fitting function, the model was able to provide acceptable agreement (within 10 nA cm−2) between simulated and experimental leakage current density for a-Si:H substrates with thicknesses of 12 and 30 μm. Additional transient simulations performed to mimic the response of the 12 μm thick device demonstrated excellent agreement (1%) with experimental data found in the literature in terms of the operating voltage required to deplete thick a-Si:H devices. The a-Si:H model developed in this work provides a method of optimizing a-Si:H based devices for particle detection applications.

History

Citation

Davis, J., Boscardin, M., Crivellari, M., Fano, L., Large, M., Menichelli, M., Morozzi, A., Moscatelli, F., Movileanu-Ionica, M., Passeri, D., Petasecca, M., Piccini, M., Rossi, A., Scorzoni, A., Thompson, B., Verzellesi, G. & Wyrsch, N. (2020). Modeling a Thick Hydrogenated Amorphous Silicon Substrate for Ionizing Radiation Detectors. Frontiers in Physics, 8 158-1-158-10.

Language

English

RIS ID

143385

Usage metrics

    Categories

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC