In vivo endorectal dosimetry of prostate tomotherapy using dual MOSkin detectors

Download (949.86 kB)
journal contribution
posted on 2024-11-15, 09:32 authored by Sarah Alnaghy, Shrikant Deshpande, Dean CutajarDean Cutajar, Kemal Berk, Peter MetcalfePeter Metcalfe, Anatoly RozenfeldAnatoly Rozenfeld
Verification of dose to the anterior rectal wall in helical tomotherapy to the prostate is important due to the close proximity of the rectal wall to the treatment field. The steep dose gradient makes these measurements challenging. A phantom-based study was completed, aimed at developing a system for measurement of anterior rectal wall doses during hypofractionated prostate stereotactic body radiotherapy (SBRT) utilizing tomotherapy delivery. An array of four dual MOSkinTM dosimeters, spaced 1 cm apart, was placed on a replica Rectafix® immobilization spacer device. This Perspex probe is a more rigid alternative to rectal balloons, to improve geometric reproducibility. The doses at each point were measured in real time and compared to doses calculated by the treatment planning system (TPS). Additionally, distance-to-agreement (DTA) measurements were acquired to assist in the comparison of measured and predicted doses. All dual MOSkin detectors measured dose to within ± 5% of the TPS at the anterior rectal wall. Whilst several points were outside of experimental error, the largest deviation from the TPS predicted dose represented a DTA of only 1.3 mm, within the acceptable DTA tolerance of 3 mm. Larger deviations of up to -11.9% were observed for the posterior and side walls; however, if acceptable DTA measurements are accounted for, then an agreement of 75% was observed. Although larger differences were observed at the other rectal wall locations, the overall effect of dose at these points was not as significant, given the lower doses. Despite the very high-dose gradient region, real-time measurements of the anterior rectal wall doses were within acceptable limits of TPS-predicted doses. The differences between measured and planned data were due to difficulties in precisely locating each detector on the TPS dose grid, which presented large variations in dose between CT voxels in regions of steep dose gradients. The dual MOSkin system would, therefore, be a useful device for detecting errors in real time, such as patient shifts or incorrect setup, during tomotherapy of the prostate.

History

Citation

Alnaghy, S. J., Deshpande, S., Cutajar, D. L., Berk, K., Metcalfe, P. & Rosenfeld, A. B. (2015). In vivo endorectal dosimetry of prostate tomotherapy using dual MOSkin detectors. Journal of Applied Clinical Medical Physics, 16 (3), 107-117.

Journal title

Journal of Applied Clinical Medical Physics

Volume

16

Issue

3

Pagination

107-117

Language

English

RIS ID

100978

Usage metrics

    Categories

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC