In this study, the heat transfer in an integrated double skin facade (DSF) and phase change material (PCM) blind system has been theoretically analysed. Both heat transfer and airflow models with CFD methods have been developed for the integrated DSF and PCM blind system. Data from an existing typical DSF building have been obtained in order to define input parameters for the simulation exercise and validate the numerical models. The temperature and velocity fields in DSF with the PCM blind system has been predicted under overheating scenario using the ANSYS Workbench FLUENT software and been compared with case of conventional aluminium blind system. This study has shown that the integrated PCM blind system was able to reduce the average air temperature and outlet temperature of the DSF while improving the convective heat transfer between the cavity air and the blades. Compared with the aluminium blind, the PCM blind can absorb large amount of excessive heat in the cavity. Overall the integrated PCM blind system has the potential to be used as an effective thermal management device for minimising the overheating effect in DSFs.

History

Citation

Li, Y., Darkwa, J. & Kokogiannakis, G. (2017). Heat transfer analysis of an integrated double skin facade and phase change material blind system. Building and Environment, 125 111-121.

Journal title

Building and Environment

Volume

125

Pagination

111-121

Language

English

RIS ID

116183

Usage metrics

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC