Evaluation of the PTW microDiamond in edge-on orientation for dosimetry in small fields
journal contribution
posted on 2024-11-16, 04:58 authored by Owen Brace, Sultan Alhujaili, Jason Paino, Duncan Butler, Dean WilkinsonDean Wilkinson, Bradley ObornBradley Oborn, Anatoly RozenfeldAnatoly Rozenfeld, Michael LerchMichael Lerch, Marco PetaseccaMarco Petasecca, Jeremy DavisJeremy Davis© 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine Purpose: The PTW microDiamond has an enhanced spatial resolution when operated in an edge-on orientation but is not typically utilized in this orientation due to the specifications of the IAEA TRS-483 code of practice for small field dosimetry. In this work the suitability of an edge-on orientation and advantages over the recommended face-on orientation will be presented. Methods: The PTW microDiamond in both orientations was compared on a Varian TrueBeam linac for: machine output factor (OF), percentage depth dose (PDD), and beam profile measurements from 10 × 10 cm2 to a 0.5 × 0.5 cm2 field size for 6X and 6FFF beam energies in a water tank. A quantification of the stem effect was performed in edge-on orientation along with tissue to phantom ratio (TPR) measurements. An extensive angular dependence study for the two orientations was also undertaken within two custom PMMA plastic cylindrical phantoms. Results: The OF of the PTW microDiamond in both orientations agrees within 1% down to the 2 × 2 cm2 field size. The edge-on orientation overresponds in the build-up region but provides improved penumbra and has a maximum observed stem effect of 1%. In the edge-on orientation there is an angular independent response with a maximum of 2% variation down to a 2 × 2 cm2 field. The PTW microDiamond in edge-on orientation for TPR measurements agreed to the CC01 ionization chamber within 1% for all field sizes. Conclusions: The microDiamond was shown to be suitable for small field dosimetry when operated in edge-on orientation. When edge-on, a significantly reduced angular dependence is observed with no significant stem effect, making it a more versatile QA instrument for rotational delivery techniques.
Funding
X-RATE: A novel radiation detector platform to realize new opportunities in radiotherapy at the Australian Synchrotron
National Health and Medical Research Council
Find out more...History
Citation
Brace, O., Alhujaili, S., Paino, J., Butler, D., Wilkinson, D., Oborn, B., Rozenfeld, A., Lerch, M., Petasecca, M. & Davis, J. (2020). Evaluation of the PTW microDiamond in edge-on orientation for dosimetry in small fields. Journal of Applied Clinical Medical Physics,Publisher website/DOI
Language
EnglishRIS ID
143370Usage metrics
Categories
Keywords
Exports
RefWorksRefWorks
BibTeXBibTeX
Ref. managerRef. manager
EndnoteEndnote
DataCiteDataCite
NLMNLM
DCDC