University of Wollongong
Browse

Evaluation of MOPITT Version 7 joint TIR-NIR XCO retrievals with TCCON

Download (7.19 MB)
journal contribution
posted on 2024-11-16, 03:54 authored by Jacob Hedelius, Tai-Long He, Dylan B A Jones, Bianca Baier, Rebecca Buchholz, Martine De Maziere, Nicholas DeutscherNicholas Deutscher, Manvendra K Dubey, Dietrich G Feist, David GriffithDavid Griffith, Frank Hase, Laura T Iraci, Pascal Jeseck, Matthaus Kiel, Rigel Kivi, Cheng Liu, Isamu Morino, Justus Notholt, Young-Suk Oh, Hirofumi Ohyama, David F Pollard, Markus Rettinger, Sebastien Roche, Coleen M Roehl, Matthias Schneider, Kei Shiomi, Kimberly Strong, Ralf Sussmann, Colm Sweeney, Yao Te, Osamu Uchino, Voltaire Velazco, Wei Wang, Thorsten Warneke, Paul O Wennberg, Helen Worden, Debra Wunch
Observations of carbon monoxide (CO) from the Measurements Of Pollution In The Troposphere (MOPITT) instrument aboard the Terra spacecraft were expected to have an accuracy of 10 % prior to the launch in 1999. Here we evaluate MOPITT Version 7 joint (V7J) thermal-infrared and near-infrared (TIR-NIR) retrieval accuracy and precision and suggest ways to further improve the accuracy of the observations. We take five steps involving filtering or bias corrections to reduce scatter and bias in the data relative to other MOPITT soundings and ground-based measurements. (1) We apply a preliminary filtering scheme in which measurements over snow and ice are removed. (2) We find a systematic pairwise bias among the four MOPITT along-track detectors (pixels) on the order of 3-4 ppb with a small temporal trend, which we remove on a global scale using a temporally trended bias correction. (3) Using a small-region approximation (SRA), a new filtering scheme is developed and applied based on additional quality indicators such as the signal-to-noise ratio (SNR). After applying these new filters, the root-mean-squared error computed using the local median from the SRA over 16 years of global observations decreases from 3.84 to 2.55 ppb. (4) We also use the SRA to find variability in MOPITT retrieval anomalies that relates to retrieval parameters. We apply a bias correction to one parameter from this analysis. (5) After applying the previous bias corrections and filtering, we compare the MOPITT results with the GGG2014 ground-based Total Carbon Column Observing Network (TCCON) observations to obtain an overall global bias correction. These comparisons show that MOPITT V7J is biased high by about 6 %-8 %, which is similar to past studies using independent validation datasets on V6J. When using TCCON spectrometric column retrievals without the standard airmass correction or scaling to aircraft (WMO scale), the ground- and satellite-based observations overall agree to better than 0.5 %. GEOS-Chem data assimilations are used to estimate the influence of filtering and scaling to TCCON on global CO and tend to pull concentrations away from the prior fluxes and closer to the truth. We conclude with suggestions for further improving the MOPITT data products.

Funding

Novel techniques for interpreting atmospheric variability and its drivers

Australian Research Council

Find out more...

History

Citation

Hedelius, J. K., He, T., Jones, D. B.A., Baier, B. C., Buchholz, R. R., de Maziere, M., Deutscher, N. M., Dubey, M. K., Feist, D. G., Griffith, D. W.T., Hase, F., Iraci, L. T., Jeseck, P., Kiel, M., Kivi, R., Liu, C., Morino, I., Notholt, J., Oh, Y., Ohyama, H., Pollard, D. F., Rettinger, M., Roche, S., Roehl, C. M., Schneider, M., Shiomi, K., Strong, K., Sussmann, R., Sweeney, C., Te, Y., Uchino, O., Velazco, V. A., Wang, W., Warneke, T., Wennberg, P. O., Worden, H. M. & Wunch, D. (2019). Evaluation of MOPITT Version 7 joint TIR-NIR XCO retrievals with TCCON. Atmospheric Measurement Techniques, 12 (10), 5547-5572.

Journal title

Atmospheric Measurement Techniques

Volume

12

Issue

10

Pagination

5547-5572

Language

English

RIS ID

139746

Usage metrics

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC