Dosimetry of microbeam radiotherapy by flexible hydrogenated amorphous silicon detectors

Download (0 kB)
journal contribution
posted on 2024-11-17, 14:58 authored by Matthew James Large, Keida Kanxheri, Jessie Posar, Saba Aziz, Aishah Bashiri, Lucio Calcagnile, Daniela Calvo, Domenico Caputo, Anna Paola Caricato, Roberto Catalano, Roberto Cirio, Giuseppe Antonio Pablo Cirrone, Tommaso Croci, Giacomo Cuttone, Gianpiero De Cesare, Paolo De Remigis, Sylvain Dunand, Michele Fabi, Luca Frontini, Catia Grimani, Mariacristina Guarrera, Maria Ionica, Francesca Lenta, Valentino Liberali, Nicola Lovecchio, Maurizio Martino, Giuseppe Maruccio, Giovanni Mazza, Mauro Menichelli
Objective. Detectors that can provide accurate dosimetry for microbeam radiation therapy (MRT) must possess intrinsic radiation hardness, a high dynamic range, and a micron-scale spatial resolution. In this work we characterize hydrogenated amorphous silicon detectors for MRT dosimetry, presenting a novel combination of flexible, ultra-thin and radiation-hard features. Approach. Two detectors are explored: an n-type/intrinsic/p-type planar diode (NIP) and an NIP with an additional charge selective layer (NIP + CSC). Results. The sensitivity of the NIP + CSC detector was greater than the NIP detector for all measurement conditions. At 1 V and 0 kGy under the 3T Cu-Cu synchrotron broadbeam, the NIP + CSC detector sensitivity of (7.76 ± 0.01) pC cGy−1 outperformed the NIP detector sensitivity of (3.55 ± 0.23) pC cGy−1 by 219%. The energy dependence of both detectors matches closely to the attenuation coefficient ratio of silicon against water. Radiation damage measurements of both detectors out to 40 kGy revealed a higher radiation tolerance in the NIP detector compared to the NIP + CSC (17.2% and 33.5% degradations, respectively). Percentage depth dose profiles matched the PTW microDiamond detector’s performance to within ±6% for all beam filtrations except in 3T Al-Al due to energy dependence. The 3T Cu-Cu microbeam field profile was reconstructed and returned microbeam width and peak-to-peak values of (51 ± 1) μm and (405 ± 5) μm, respectively. The peak-to-valley dose ratio was measured as a function of depth and agrees within error to the values obtained with the PTW microDiamond. X-ray beam induced charge mapping of the detector revealed minimal dose perturbations from extra-cameral materials. Significance. The detectors are comparable to commercially available dosimeters for quality assurance in MRT. With added benefits of being micron-sized and possessing a flexible water-equivalent substrate, these detectors are attractive candidates for quality assurance, in-vivo dosimetry and in-line beam monitoring for MRT and FLASH therapy.

Funding

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (1061 DEL 10.8.2021)

History

Journal title

Physics in Medicine and Biology

Volume

69

Article/chapter number

155022

Language

English

Usage metrics

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC