Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy

Download (510.65 kB)
journal contribution
posted on 2024-11-15, 09:58 authored by Vikneswary Batumalai, Penny Phan, Callie Choong, Lois HollowayLois Holloway, Geoff P Delaney
Introduction To compare the differences in setup errors measured with electronic portal image (EPI) and cone-beam computed tomography (CBCT) in patients undergoing tangential breast radiotherapy (RT). Relationship between setup errors, body mass index (BMI) and breast size was assessed. Methods Twenty-five patients undergoing postoperative RT to the breast were consented for this study. Weekly CBCT scans were acquired and retrospectively registered to the planning CT in three dimensions, first using bony anatomy for bony registration (CBCT-B) and again using breast tissue outline for soft tissue registration (CBCT-S). Digitally reconstructed radiographs (DRR) generated from CBCT to simulate EPI were compared to the planning DRR using bony anatomy in the V (parallel to the cranio-caudal axis) and U (perpendicular to V) planes. The systematic (Σ) and random (σ) errors were calculated and correlated with BMI and breast size. Results The systematic and random errors for EPI (ΣV = 3.7 mm, ΣU = 2.8 mm and σV = 2.9 mm, σU = 2.5) and CBCT-B (ΣV = 3.5 mm, ΣU = 3.4 mm and σV = 2.8 mm, σU = 2.8) were of similar magnitude in the V and U planes. Similarly, the differences in setup errors for CBCT-B and CBCT-S in three dimensions were less than 1 mm. Only CBCT-S setup error correlated with BMI and breast size. Conclusions CBCT and EPI show insignificant variation in their ability to detect setup error. These findings suggest no significant differences that would make one modality considered superior over the other and EPI should remain the standard of care for most patients. However, there is a correlation with breast size, BMI and setup error as detected by CBCT-S, justifying the use of CBCT-S for larger patients.

History

Citation

Batumalai, V., Phan, P., Choong, C., Holloway, L. & Delaney, G. P. (2016). Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy. Journal of Medical Radiation Sciences, 63 (4), 224-231.

Journal title

Journal of Medical Radiation Sciences

Volume

63

Issue

4

Pagination

224-231

Language

English

RIS ID

111113

Usage metrics

    Categories

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC