posted on 2024-11-16, 04:41 authored by Anna Romanyukha, Mauro Carrara, Davide Mazzeo, Chiara Tenconi, Tebarak Al-Salmani, Joel PoderJoel Poder, Dean CutajarDean Cutajar, Iolanda FuduliIolanda Fuduli, Marco PetaseccaMarco Petasecca, Joseph A Bucci, Annamaria Cerrotta, Brigida Pappalardi, Federica Piccolo, Emanuele Pignoli, Anatoly RozenfeldAnatoly Rozenfeld
The multichannel vaginal cylinder (MVC) applicator employed for gynecological high dose rate (HDR) brachytherapy increases dose delivery complexity, and thus makes the treatment more prone to errors. A quality assurance (QA) procedure tracking the source throughout dose delivery can detect dwell position and time errors in the multiple channels of the applicator. A new MVC system with integrated real time in vivo treatment delivery QA has been developed based on diodes embedded on the outer surface of the MVC. It has been pre-calibrated and verified using a non-clinical treatment plan with consecutive test positions and dwell times within each catheter, followed by the delivery of ten clinical plans of adjuvant vaginal cuff brachytherapy following hysterectomy for endometrial cancer. The non-clinical verification showed overall mean dwell position and time discrepancies between the nominal and measured treatment of −0.2 ± 0.5 mm and −0.1 ± 0.1 s (k = 1), respectively. The clinical plans showed mean positional discrepancies of 0.2 ± 0.4 and 0.0 ± 0.8 mm, for the central and peripheral catheters, respectively, and mean dwell time discrepancies of −0.1 ± 0.2 and −0.0 ± 0.1 s for central and peripheral catheters, respectively. The innovative prototype of the MVC system has shown the ability to track the source with sub-mm and sub-second accuracy, and demonstrated potential for its incorporation into the clinical routine.

Funding

Out of Asia: unique insights into human evolution and interactions using frontier technologies in archaeological science

Australian Research Council

Find out more...

History

Citation

Romanyukha, A., Carrara, M., Mazzeo, D., Tenconi, C., Al-Salmani, T., Poder, J., Cutajar, D., Fuduli, I., Petasecca, M., Bucci, J., Cerrotta, A., Pappalardi, B., Piccolo, F., Pignoli, E. & Rosenfeld, A. (2019). An innovative gynecological HDR brachytherapy applicator system for treatment delivery and real-time verification. Physica Medica: an international journal devoted to the applications of physics to medicine and biology, 59 151-157.

Journal title

Physica Medica

Volume

59

Pagination

151-157

Language

English

RIS ID

133847

Usage metrics

    Categories

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC