University of Wollongong
Browse

2D monolithic silicon-diode array detectors in megavoltage photon beams: does the fabrication technology matter? A medical physicist's perspective

Download (988.28 kB)
journal contribution
posted on 2024-11-16, 03:06 authored by Nauljun Stansook, Giordano Biasi, Kananan Utitsarn, Marco PetaseccaMarco Petasecca, Peter MetcalfePeter Metcalfe, Martin Carolan, Michael LerchMichael Lerch, Vladimir Perevertaylo, Tomas KronTomas Kron, Anatoly RozenfeldAnatoly Rozenfeld
A family of prototype 2D monolithic silicon-diode array detectors (MP512, Duo, Octa) has been proposed by the Centre for Medical Radiation Physics, University of Wollongong (Australia) for relative dosimetry in small megavoltage photon beams. These detectors, which differ in the topology of their 512 sensitive volumes, were originally fabricated on bulk p-type substrates. More recently, they have also been fabricated on epitaxial p-type substrates. In the literature, their performance has been individually characterized for quality assurance (QA) applications. The present study directly assessed and compared that of a MP512-bulk and that of a MP512-epitaxial in terms of radiation hardness, long-term stability, response linearity with dose, dose per pulse and angular dependence. Their measurements of output factors, off-axis ratios and percentage depth doses in square radiation fields collimated by the jaws and produced by 6 MV and 10 MV flattened photon beams were then benchmarked against those by commercially available detectors. The present investigation was aimed at establishing, from a medical physicist's perspective, how the bulk and epitaxial fabrication technologies would affect the implementation of the MP512s into a QA protocol. Based on results, the MP512-epitaxial would offer superior radiation hardness, long-term stability and achievable uniformity and reproducibility of the response across the 2D active area.

Funding

Improving radiation therapy of static and moving targets using high spatial resolution real-time dosimeters

National Health and Medical Research Council

Find out more...

History

Citation

Stansook, N., Biasi, G., Utitsarn, K., Petasecca, M., Metcalfe, P., Carolan, M., Lerch, M. L. F., Perevertaylo, V. L., Kron, T. & Rosenfeld, A. B. (2019). 2D monolithic silicon-diode array detectors in megavoltage photon beams: does the fabrication technology matter? A medical physicist's perspective. Australasian Physical and Engineering Sciences in Medicine, 42 (2), 443-451.

Journal title

Australasian Physical and Engineering Sciences in Medicine

Volume

42

Issue

2

Pagination

443-451