This paper examines the flow properties of three powders determined using the traditional Jenike Direct Shear Tester and the Peschl Rotational Split Level (RSL) Shear Tester. Both instantaneous yield loci and wall yield loci measurements are compared.
History
Citation
Halford, W. G. Arnold, P. C. (2007). Some observations on the design data provided by three well known devices for measuring flow properties of bulk solids. International Conference for Bulk Materials Storage, Handling and Transportation Barton, ACT: Engineers Australia.
Parent title
9th International Conference on Bulk Materials Storage, Handling and Transportation, ICBMH 2007