University of Wollongong
Browse

Measuring multiple parameters in a self-mixing optical feedback system

Download (176.16 kB)
conference contribution
posted on 2024-11-14, 10:54 authored by Yanguang YuYanguang Yu, Jiangtao XiJiangtao Xi, Enbang LiEnbang Li, Jose ChicharoJose Chicharo, Thierry Bosch
We propose a new approach that yields the values of multiple parameters at the same time for self-mixing optical feedback interferometric systems. These parameters are the linewidth enhancement factor of Semiconductor Lasers, the optical feedback level factor as well as vibration information of a target including the frequency and the amplitude. The method is based on optical feedback interferometry. Its effectiveness has been confirmed by computer simulations and experiments.

History

Citation

This paper originally appeared as: Yu, Y, Xi, J, Li, E et al, Measuring multiple parameters in a self-mixing optical feedback system, 2004 Conference on Optoelectronic and Microelectronic Materials and Devices, December 2004, 253-256. Copyright IEEE 2004.

Parent title

Conference on Optoelectronic and Microelectronic Materials and Devices, Proceedings, COMMAD