University of Wollongong
Browse

Laboratory Determination of Efficiency of Prefabricated Vertical Drains Incorporating Vacuum Preloading

Download (151.97 kB)
conference contribution
posted on 2024-11-13, 13:52 authored by Buddhima Indraratna, Cholachat Rujikiatkamjorn
This paper is mainly concerned with a laboratory study to investigate the effect of vacuum preloading. Two separate series of tests were conducted in a large-scale consolidation apparatus designed and installed at the University of Wollongong, with axial load increments of 30 and 50 kPa. The first series of tests were performed based on the conventional method (i.e. without vacuum preloading). For the second series, a vacuum pressure of 100 kPa was applied during the process of consolidation. The corresponding settlement behaviour was recorded and plotted. The extent of smear zone was examined by the variation of permeability of small specimens obtained from the large-scale consolidometer. The void ratio-permeability relationship was also determined from the small specimens. The test results based on the large-scale laboratory testing confirm the efficiency of vacuum preloading in comparison with the conventional method of surcharge alone.

History

Citation

This conference paper was originally published as Indraratna, B and Rujikiatkamjorn C, Laboratory Determination of Efficiency of Prefabricated Vertical Drains Incorporating Vacuum Preloading, in Proceedings of the 15th Southeast Asian Geotechnical Conference, Bangkok, Thailand, 22-26 November 2004, 1, 453-456. Original conference proceedings here.

Pagination

453-456

Language

English

RIS ID

10568

Usage metrics

    Categories

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC